Made completely of stainless steel.
Polymerizes 18 flasks with clamp 030390.
The M-9 polymerizer is equipped with a processor to change temperature according to a pre-set programme.
On the M-9 the operator (user) can select the following:
a) A delayed start time set in hours and minutes from 0.00 to 99 hours 59 minutes. This means the programme can be pre-set to start at a specific time. The delay works every time the programme is initiated.
b) The duration of each temperature increase gradient in hours and minutes from 0.00 to 99 hours 59 minutes.
c) The desired holding time in hours and minutes from 0.00 to 99 hours 59 minutes at each plateau.
END OF TREATMENT WARNING BUZZER
– When the programme completes treatment or A4 a modulated warning buzzer is set off for one minute. When the alarm buzzer sounds, press any key to acknowledge the alarm and continue the programme.
– If the power fails the regulator stores all its data, and when power returns it continues from the same point in the programme.
– Programmes and parameters are stored indefinitely when power to the regulator is cut off.
Technical features
Power supply: 230 V, 50/60 Hz
Power: 3000 W
Weight: 20 kg
Outside dimensions:
Height with handle: 510 mm
Width con llave: 420 mm
Lenght: 500 mm
Inside dimensions:
Height: 350 mm
Width: 320 mm
Lenght: 400 mm